- CURRENT
Charge: constant current, adjustable: 0 to
1.000A, in steps of 1mA (0.001A).
Discharge: constant current, adjustable: 0 to 6.00A, in steps of 10mA (0.01A).
- VOLTAGE
Charge: 0 to 40V.
Discharge: 3 to 24V at full current, up to 44V at
reduced current (144W max power dissipation).
- MODES
CC - Constant Current Charge.
CV - Constant Current Charge followed by Constant Voltage Charge.
PEAK - Constant Current Charge and stop at Peak Voltage.
ANALYSIS - Capacity Test Discharge.
DISCH - Full discharge.
- VOLTAGE CONTROL
Adjustable: Usable from 3.00 to 44.0V, with an
accuracy of 1% ±0.1V.
- METERS
Voltage: 3-1/2 digit, LCD digital panel meter, 0
to 19.99 and 199.9V scales.
Current: 3-1/2 digit, LCD digital panel meter, 0 to 1.999A scale for charge and 0 to
19.99A scale for discharge.
- STATUS INDICATORS
RUN - Output is on.
CYCLE END - Pulsating (with beeper) to indicate end of a peak charge cycle or any timed
cycle.
PEAK VOLTAGE - The battery has charged to the programmed peak voltage.
VOLTAGE FAULT - Reversed polarity or overvoltage.
CAPACITY FAILURE - Low battery voltage on analysis.
- CONTROLS
Mode selector switch, RUN-RESET switch, voltmeter
scale selector switch, timer speed switch and potentiometer to select the charge and
discharge currents.
- TIMER
External, optional (Timer
24).
- OVERCURRENT PROTECTION
Input (line), Charge
output, Discharge output.
- LINE VOLTAGE
115/230VAC ±10%,
50-60Hz.
- AMBIENT
+5oC to +35oC (Consult
factory for extended temperature operation).