JFM logo trback.gif (19164 bytes) JFM Engineering, Inc.
Miami, Florida
U.S.A.
   May Almighty God protect all of those in action in Iraq .

[Home] [Articles] [Battery Testing] [Contact us] [Credit card orders] [Español] [FAQs] [Links] [Manuals] [Products] [Services]
[Technical Bulletins] [Technical Notes] [Upgrades] [What is new?] [Who are we?] 


 

 

AQS logo trback.gif (3614 bytes)24-400L
Battery Charger-Analyzer for small battery systems (up to 10A-Hr)

24-400l.jpg (224219 bytes) 

  • The 24-400L is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.
  • With its multiple modes of operation of Constant Current Charge, Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis) and Full Discharge (deep cycle), the 24-400L can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.
  • The charger features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and overvoltage conditions.
  • Two large LED digital meters permit the simultaneous monitoring of voltage and current, while six indicator lights inform of the status of the operation.
  • An optional external electronic timer (Timer 24) complements the 24-400L charge and discharge operations in applications requiring a time limit.

 

SPECIFICATIONS 

  1. CURRENT
  2. Charge: constant current, adjustable: 0 to 1.000A, in steps of 1mA (0.001A).
    Discharge: constant current, adjustable: 0 to 6.00A, in steps of 10mA (0.01A).

  3. VOLTAGE
  4. Charge: 0 to 40V.
    Discharge: 3 to 24V at full current, up to 44V at reduced current (144W max power dissipation).

  5. MODES
  6. CC - Constant Current Charge.
    CV - Constant Current Charge followed by Constant Voltage Charge.
    PEAK - Constant Current Charge and stop at Peak Voltage.
    ANALYSIS - Capacity Test Discharge.
    DISCH - Full discharge.

  7. VOLTAGE CONTROL
  8. Adjustable: Usable from 3.00 to 44.0V, with an accuracy of 1% ±0.1V.

  9. METERS
  10. Voltage: 3-1/2 digit, LCD digital panel meter, 0 to 19.99 and 199.9V scales.    
    Current: 3-1/2 digit, LCD digital panel meter, 0 to 1.999A scale for charge and 0 to 19.99A scale for discharge.  

  11. STATUS INDICATORS
  12. RUN - Output is on.
    CYCLE END - Pulsating (with beeper) to indicate end of a peak charge cycle or any timed cycle.
    PEAK VOLTAGE - The battery has charged to the programmed peak voltage.
    VOLTAGE FAULT - Reversed polarity or overvoltage.
    CAPACITY FAILURE - Low battery voltage on analysis.

  13. CONTROLS
  14. Mode selector switch, RUN-RESET switch, voltmeter scale selector switch, timer speed switch and potentiometer to select the charge and discharge currents.

  15. TIMER
  16. External, optional (Timer 24).

  17. OVERCURRENT PROTECTION
  18. Input (line), Charge output, Discharge output.

  19. LINE VOLTAGE
  20. 115/230VAC ±10%, 50-60Hz.

  21. AMBIENT
  22. +5oC to +35oC (Consult factory for extended temperature operation).

Note: Specifications subject to change without notice

    back to top

 

 

 

Send mail to webmaster@jfmeng.com with questions or comments about this web site.