JFM logo trback.gif (19164 bytes) JFM Engineering, Inc.
Miami, Florida
U.S.A.
   May Almighty God protect all of those in action in Iraq .

[Home] [Articles] [Battery Testing] [Contact us] [Credit card orders] [Español] [FAQs] [Links] [Manuals] [Products] [Services]
[Technical Bulletins] [Technical Notes] [Upgrades] [What is new?] [Who are we?] 


 

JFM logo trback.gif (19164 bytes) BCA-1210
Battery Charger-Analyzer for small battery systems (up to 10A-Hr)

BCA-1210 - 1.JPG (46956 bytes)

 

  • The BCA-1210 is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.
  • With its multiple modes of operation of Constant Current Charge, Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis) and Full Discharge (deep cycle), the BCA-1210 can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.
  • The charger features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and overvoltage conditions.
  • Two large LED digital meters permit the simultaneous monitoring of voltage and current, while six indicator lights inform of the status of the operation.
  • An integral electronic timer (w/battery back-up) complements the BCA-1210 charge and discharge operations in applications requiring a time limit.

 

SPECIFICATIONS 

  1. CURRENT
  2. Charge: constant current, adjustable: 0 to 1.999A, in steps of 1mA (0.001A).
    Discharge: constant current, adjustable: 0 to 10.00A, in steps of 10mA (0.01A).

  3. VOLTAGE
  4. Charge: 0 to 40V.
    Discharge: 3 to 24V at full current, up to 44V at reduced current (240W max power dissipation).

  5. MODES
  6. CC - Constant Current Charge.
    CV - Constant Current Charge followed by Constant Voltage Charge.
    PEAK - Constant Current Charge and stop at Peak Voltage.
    ANALYSIS - Capacity Test Discharge.
    DISCH - Full discharge.

  7. VOLTAGE CONTROL
  8. Adjustable: Usable from 3.00 to 44.0V, with an accuracy of 1% ±.1V.

  9. METERS
  10. Voltage: 3-1/2 digit, LED digital panel meter, 0 to 19.99 and 199.9V scales.    
    Current: 3-1/2 digit, LED digital panel meter, 0 to 1.999A scale for charge and 0 to 19.99A scale for discharge.  

  11. STATUS INDICATORS
  12. RUN - Output is on.
    CYCLE END - Pulsating (with beeper) to indicate end of a peak charge cycle or any timed cycle.
    PEAK VOLTAGE - The battery has charged to the programmed peak voltage.
    VOLTAGE FAULT - Reversed polarity or overvoltage.
    CAPACITY FAILURE - Low battery voltage on analysis.

  13. CONTROLS
  14. Mode selector switch, RUN-RESET switch, voltmeter scale selector switch, timer speed switch and potentiometer to select the charge and discharge currents.

  15. TIMER
  16. Internal, four digit readout with two digit selector and a speed control switch for HH:MM, MM:SS and high speed test.

  17. OVERCURRENT PROTECTION
  18. Input (line), Charge output, Discharge output.

  19. LINE VOLTAGE
  20. 115/230VAC ±10%, 50-60Hz.

  21. AMBIENT
  22. +5oC to +35oC (contact factory for extended temperature operation).

  23. PART NUMBER
    9891121001
  24. APPROVALS
  25. NSN 6130-01-434-1615

Note: Specifications subject to change without notice