SuperMasterCharger
Battery Charger-Analyzer for
large battery systems (10A-hr
to 100A-hr)
(advanced version of the earlier
MasterCharger)
- he 24-400XG
is an instrument designed to charge, trickle charge and analyze (discharge)
Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.
The SuperMasterCharger
is an instrument designed to charge, trickle charge and analyze (discharge)
Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.
With its multiple modes of operation of
Constant Current Charge (dual and single rate),
Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic
Discharge (analysis), Resistance Discharge (analysis)
and Full Discharge (deep cycle), the SuperMasterCharger
can satisfy the requirements of most large (10 A-hr
to 100A-hr) rechargeable battery systems.
The instrument
features safety interlocks to protect the operator, the charger and the battery
in the event of reversed polarity connection, short circuit, open circuit (no
load) and Overvoltage conditions.
Two large LED digital meters permit the
simultaneous monitoring of voltage and current, while eight
indicator lights inform of the status of the operation.
Storage (nonvolatile)
of battery test profiles
Battery temperature
monitoring
Microprocessor
based timer with HH:MM and MM:SS timing selection
Interfacing
to the BTAS16 Computerized Battery Test System for
monitoring, programming and control
Suggested
Accessory: we recommend the VCM-100 to simplify
the task of testing and calibration the Charger-Analyzer.
SPECIFICATIONS
CURRENT
Charge: constant current, programmable: 0 to
50.0A, in steps of 0.1A.
Discharge: constant current, programmable: 0 to
60.0A, in steps of 0.1A.
VOLTAGE
Charge: 0 to 77V
Discharge: 3 to 24V at full current, and up to
48V at reduced current (power dissipation
limited).
MODES
Constant Current Charge
Single Rate
Single Rate with stop at peak voltage
Dual Rate
Dual Rate with transfer at peak voltage
(all with optional Overvoltage)
Constant Voltage Charge.
Constant Current followed by Constant Voltage
Discharge
Constant Current Capacity Test
Constant Resistance Load Capacity Test
Full Discharge
VOLTAGE CONTROL
Adjustable: Usable from 3.00 to 80.0V, with an
accuracy of 2% ± 0.1V
METERS
Voltage: 3-1/2 digit, LED digital panel meter, 0 to 19.99V
and 199.9V scales.
Current: 3-1/2 digit, LED digital panel meter, 0 to 199.9A
scale for charge and discharge.
CONTROLS
24 button keypad to select the Test Mode,
program the Test Parameters and view status and results.
DISPLAY
LCD readout with 4 lines x 20 characters.
STATUS INDICATORS
RESET and CYCLE END.
MAIN and TOPPING CHARGE.
DISCHARGE.
PEAK VOLTAGE END.
CAPACITY FAILURE END.
WARNING and FAULT
TIMER
Microprocessor controlled with HH:MM
and MM:SS elapsed time selection.
PROTECTION
Battery Overtemp
Battery Temperature monitoring by way of an external cable or
Temp-Plate
Overheat
Monitoring of internal Heat Dissipators
Power Failure
Internal rechargeable battery.
Current
Microprocessor monitored for over and under current faults
Fusing for Line, Charge
output and Discharge output.
LINE VOLTAGE
115VAC (limited charge capability) /
208,230,245VAC ±10%, 50-60Hz.
AMBIENT
+5oC to +35oC (contact factory for extended
temperature operation).
PART NUMBER
9899603001
APPROVALS
TBA
ACCESSORIES INCLUDED
BATTERY CABLE:
Cable to connect the Charger-Analyzer to one or two batteries
TEMP-PLATE: Plate to measure
the temperature of the battery(ies)
SINGLE CELL ADAPTOR: Short cable with clips to charge a single cell or a group
of cells
MISC: Fuses and Current Limiter
BROCHURE
MANUAL
Note:
Specifications subject to change without notice
  
|