VCM-100
Calibrator for Battery Charger-Analyzers
- The VCM 100 is an instrument designed to
verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium,
Lead-Acid and other types of batteries. It is principally designed for the Superseder line
of battery test instruments but it can also be applied to other types of chargers and
charger-analyzers.
- The instrument is basically a digital
Ammeter and Voltmeter that is connected between the charger under test and the battery. In
addition, it provides a low current adjustable voltage source to simulate the various
battery voltage cut-off points and a Temp-Plate simulator to test the battery overtemp
portion of the Superseder line of Charger-Analyzers.
- Two 3-1/2 digit LED meters provide the
simultaneous monitoring of voltage and current on the charger and battery under test. The
voltmeter can also be used independently by way of the two external meter lead jacks.
- Current and voltage measurement can be
performed through the external cables, fitted with a Battery Cable Plug and a Battery
Receptacle, or through the front panel binding posts, for other types of tests (at reduced
currents).
SPECIFICATIONS
- CURRENT CAPACITY
Through the rear posts: 50A max, continuous, 100A
max, intermittent.
Through the front panel binding posts: 10A max.
- VOLTAGE MEASUREMENT CAPACITY
0 to 20V (19.90V) or 0 to 200V (199.9), internal
or external.
- VOLTAGE SOURCE
Externally adjustable: 0 to 100V, 25mA max.
- METERS
Type: LED, 3-1/2 digit.
Voltage: 0 to 19.9V and 0 to 199.9V.
Current: 0 to 199.9A
- CONTROLS
Voltmeter source and scale selector.
Potentiometer for calibrator voltage adjustment.
Calibrator ON LINE/OFF (connected to the output/disconnected) selector switch.
Calibrator polarity (normal and reverse) selector switch.
Thermistor selector switch.
Thermistor temperature simulator selector switch.
Power ON/OFF switch (on rear power block).
Line voltage selector (on rear power block).
- CONNECTORS
Front panel binding posts (fused).
External voltmeter meter banana jacks.
Rear posts with cables with battery connectors.
Shunt monitor banana jacks.
Temp-Plate simulator cable connector.
- OVERCURRENT PROTECTION
Power (line) and Output (for low current binding
posts only).
- LINE VOLTAGE
115/230VAC +-10%, 50-60Hz.
- AMBIENT
5o C to 35o C.
- PART NUMBER
9891064001
Note: Specifications subject
to change without notice
  
|