JFM Engineering, Inc. - Miami, Florida, USA


 

JFM logo trback.gif (19164 bytes) BCA-1210
Battery Charger-Analyzer for small battery systems (up to 10A-Hr)

BCA-1210 - 1.JPG (46956 bytes)

 

  • The BCA-1210 is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.
  • With its multiple modes of operation of Constant Current Charge, Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis) and Full Discharge (deep cycle), the BCA-1210 can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.
  • The charger features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and overvoltage conditions.
  • Two large LED digital meters permit the simultaneous monitoring of voltage and current, while six indicator lights inform of the status of the operation.
  • An integral electronic timer (w/battery back-up) complements the BCA-1210 charge and discharge operations in applications requiring a time limit.

 

SPECIFICATIONS 

1.1 CURRENT:

Charge: constant current, adjustable: 0 to 1.999A, in steps of 1mA (0.001A).
Discharge: constant current, adjustable: 0 to 10.00A, in steps of 10mA (0.01A).

1.2 VOLTAGE:

Charge: 0 to 40V.
Discharge: 3 to 24V at full current, up to 44V at reduced current (240W max power dissipation).

1.3 MODES:

CC - Constant Current Charge.
CV - Constant Current Charge followed by Constant Voltage Charge.
PEAK - Constant Current Charge and stop at Peak Voltage.
ANALYSIS - Capacity Test Discharge.
DISCH - Full discharge.

1.4 VOLTAGE CONTROL:

Adjustable: Usable from 3.00 to 44.0V, with an accuracy of 1% ±.1V.

1.5 METERS:

Voltage: 3-1/2 digit, LED digital panel meter, 0 to 19.99 and 199.9V scales.    
Current: 3-1/2 digit, LED digital panel meter, 0 to 1.999A scale for charge and 0 to 19.99A scale for discharge.  

1.6 STATUS INDICATORS:

RUN - Output is on.
CYCLE END - Pulsating (with beeper) to indicate end of a peak charge cycle or any timed cycle.
PEAK VOLTAGE - The battery has charged to the programmed peak voltage.
VOLTAGE FAULT - Reversed polarity or overvoltage.
CAPACITY FAILURE - Low battery voltage on analysis.

1.7 CONTROLS:

Mode selector switch, RUN-RESET switch, voltmeter scale selector switch, timer speed switch and potentiometer to select the charge and discharge currents.

1.8 TIMER:

Internal, four digit readout with two digit selector and a speed control switch for HH:MM, MM:SS and high speed test.

1.9 FUSES:

Input (line), Charge output, Discharge output.

1.10 LINE VOLTAGE:

115/230VAC ±10%, 50-60Hz.

1.11 AMBIENT:

+5oC to +35oC (contact factory for extended temperature operation).

1.12 PART NUMBER:

9891121001

Note: Specifications subject to change without notice

back to top

 


Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Phone

 

 


[Home] [Articles] [Battery Testing] [Contact us] [Credit card orders] [Español] [FAQs] [Links] [Manuals] [Products] [Services]
[Technical Bulletins] [Technical Notes] [Upgrades] [What is new?] [Who are we?] 
Send mail to webmaster@jfmeng.com with questions or comments about this web site.
Copyright © 2009 JFM Engineering, Inc. --- Last modified: April 19, 2009