BCA-1210
Battery Charger-Analyzer for small battery systems
(up to 10A-Hr)
- The BCA-1210 is an instrument designed to charge,
trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of
rechargeable batteries.
- With its multiple modes of operation of Constant
Current Charge, Constant Current & Float Charge, Constant Current & Peak Stop
Charge, Automatic Discharge (analysis) and Full Discharge (deep cycle), the BCA-1210 can
satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.
- The charger features safety interlocks to protect
the operator, the charger and the battery in the event of reversed polarity connection,
short circuit, open circuit (no load) and overvoltage conditions.
- Two large LED digital meters permit the simultaneous
monitoring of voltage and current, while six indicator lights inform of the status of the
operation.
- An integral electronic timer (w/battery back-up)
complements the BCA-1210 charge and discharge operations in applications requiring a time
limit.
SPECIFICATIONS
1.1 CURRENT:
Charge: constant current, adjustable: 0 to 1.999A,
in steps of 1mA (0.001A).
Discharge: constant current, adjustable: 0 to 10.00A, in steps of 10mA (0.01A).
1.2 VOLTAGE:
Charge: 0 to 40V.
Discharge: 3 to 24V at full current, up to 44V at reduced current (240W max power
dissipation).
1.3 MODES:
CC - Constant Current Charge.
CV - Constant Current Charge followed by Constant Voltage Charge.
PEAK - Constant Current Charge and stop at Peak Voltage.
ANALYSIS - Capacity Test Discharge.
DISCH - Full discharge.
1.4 VOLTAGE CONTROL:
Adjustable: Usable from 3.00 to 44.0V,
with an accuracy of 1% ±.1V.
1.5 METERS:
Voltage: 3-1/2 digit, LED digital panel meter, 0
to 19.99 and 199.9V scales.
Current: 3-1/2 digit, LED digital panel meter, 0 to 1.999A scale for charge and 0 to
19.99A scale for discharge.
1.6 STATUS INDICATORS:
RUN - Output is on.
CYCLE END - Pulsating (with beeper) to indicate end of a peak charge cycle or any timed
cycle.
PEAK VOLTAGE - The battery has charged to the programmed peak voltage.
VOLTAGE FAULT - Reversed polarity or overvoltage.
CAPACITY FAILURE - Low battery voltage on analysis.
1.7 CONTROLS:
Mode selector switch, RUN-RESET switch,
voltmeter scale selector switch, timer speed switch and potentiometer to select the charge
and discharge currents.
1.8 TIMER:
Internal, four digit readout with two digit selector and a speed control switch for HH:MM, MM:SS and high speed test.
1.9 FUSES:
Input (line), Charge output, Discharge output.
1.10 LINE VOLTAGE:
115/230VAC ±10%, 50-60Hz.
1.11 AMBIENT:
+5oC to +35oC (contact factory for extended
temperature operation).
1.12 PART NUMBER:
9891121001
Note:
Specifications subject to change without notice
back to